8-16 FL11.0CTR
AMP+11V is not output.
FLOW CHART NO.6
Is approximately
+12V voltage supplied to the
cathode of D629?
Check C623, D629, D630, D661 and their periphery
circuit, and service it if defective.
Ye s
No
Check if there is
any leak or short-circuit on
the loaded circuit, and ser
vice it if defective.
P-ON+21V is not output.
FLOW CHART NO.5
Is approximately +21V voltage supplied to the
cathode of D619?
Check C616, C632, C633, D619, D620 and their
periphery circuit, and service it if defective.
Ye s
No
Check if there is any leak or short-circuit on
the loaded circuit, and service it if de
fective.
Check if there is any leak or short-circuit on
the loaded circuit, and service it if defective.
AL+5V is not output.
FLOW CHART NO.7
Is approximately +
6V voltage supplied to the
cathode of D627?
Ye s
Check C622, D62
7, D635, D636, D637, D640, D641, Q611
and their periphery circuit, and service it if defective
.
No