8-2 FL11.0ATR
Check Q211, Q212, P-ON-H1 line and their periphery
circuit, and service it if defective.
PANEL+24V is not output.
FLOW CHART NO.6
Is approximately
+24V voltage supplied to the emitter
of Q211?
No
Ye s
See FLOW CHART No.5 <P-ON+24V is not output.>
Replace IC202.
Is approximately +
4V voltage supplied to Pin(2) of
IC202?
Ye s
No
Check Q202, Q203, D201, P-ON-H1
line and their
peripher
y circuit, and service it if def
ective.
No
PANEL+13V is not output.
FLOW CHART NO.7
Is approximately +17V voltage supplied to Pin(1) of
IC202?
Ye s
Check C631, D631, D668
and their periphery circuit,
and service it if defec
tive.
+11V(AMP+11V) is not output.
FLOW CHART NO.8
Is approximately +11V voltage supplied to the
cathode of D670?
Check C695, D670, D671, D672 and their periphery
circuit, and service it if defective.
Ye s
No
Check if there is
any leak or short-circuit on
the loaded circuit, and ser
vice it if defective.
P-ON+24V is not output.
FLOW CHART NO.5
Is approximately +24V voltage supplied to the
cathode of D632?
Check C632, D632, D633 and their periphery
circuit, and service it if defective.
Ye s
No
Check if there is any leak or short-circuit on
the loaded circuit, and service it if de
fective.