9-16
FL11.0CBLP
5. Power Supply Block Diagram
CAUTION !
Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit.
If Main Fuse (F601) is blown , check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
For continued protection against risk of fire,
replace only with same type 4 A, 125V fuse.
CAUTION ! :
ATTENTION : Utiliser un fusible de rechange de même type de 4A, 125V.
4A/125V
NOTE:
The voltage for parts in hot circuit is measured using
hot GND as a common terminal.
HOT COLD
MAIN CBA
HOT CIRCUIT. BE CAREFUL.
Q608
SWITCHING
CONTROL
14
3 2
IC601
T601
1
LINE
FILTER
L601
CN603
BRIDGE
RECTIFIER
D609- D612
3
2
7
8
9
10
11
12
5
6
FEED
BACK
Q607
SWITCHING
Q609
CN601
Q611
Q616
Q631
AC601
AC CORD
4A/125V
F601
4A/125V
Q610
TO
SYSTEM CONTROL
BLOCKDIAGRAM
P-ON-H2
+5V REG.
PROTECT1
P-ON+21V
11
P-ON+21V
AMP+11V
AL+5V
DIGITAL MAIN CBA UNIT
13,14
16,17
AMP+11V6,7
P-ON+21V3,4
AL+5V9