5-1 LC9EA
ELECTRICAL ADJUSTMENT INSTRUCTIONS
General Note: “CBA” is abbreviation for
“Circuit Board Assembly.
Note: Electrical adjustments are required after
replacing circuit components and certain
mechanical parts. It is important to perform
these adjustments only after all repairs and
replacements have been completed.
Also, do not attempt these adjustments unless
the proper equipment is available.
Test Equipment Required
1. Remote control unit
2. Color Analyzer,
CA-310 (KONICA MINOLTA Luminance meter) or
measuring instrument as good as CA-310.
How to set up the service mode:
Service mode:
1. Turn the power on.
2. Press [MENU] button to display Setup menu.
3. Select “Features”.
4. Select “Current Software Info”.
5. Press [0], [4], [2], [5], [7], [4] and [INFO] buttons on
the remote control unit in this order. The following
screen appears.
Code:
Pic code:
Panel-Option code:
MIPS:
Press "POWER" key to exit.
*******-**-**-****-**
**********-***-*-**
**-***-***-***-***
Push 0 key
Tuner:
Safety:
HDMI EDID:
PC EDID:
****-*****-****
Safety_Non
**
**
Total Watch Time:
Lightsensor:
*****
****
"
*
" differs depending on the models.